Friday, January 29, 2010

COBOL Tutorials

COBOL Tutorial
Computer Programming
A Program is a set of instructions that enables a computer to process data, there are two types of computer programs which are 1- Operating system programs, which control the overall operation of the system and 2- Applications programs, it is the actuall program tasks requried by the users. The term used to descriebe all type of programs is called software in general application program reads input , process it, and produce information or out put the user neads. A set of computerized business procedures in an application area is called an information systems.
Application program development process
1. Determain program specifications.
2. Design the program planning tools.
3. Code and enter the program.
4. Compile the program.
5. Test the program.
6. Document the program.
History of Cobol.
Developed by 1959 by a group called COnference on Data Systems Language (CODASYL). First COBOL compiler was released by December 1959.
First ANSI approved version 1968
Modified ANSI approved version 1974 (OS/VS COBOL)
Modified ANSI approved version 1985 (VS COBOL 2)

This book is written based on IBM COBOL for OS/390 V2R2.
Interduction to Cobol
COBOL is a high-level programming language first developed by the CODASYL Committee (Conference on Data Systems Languages) in 1960. Since then, responsibility for developing new COBOL standards has been assumed by the American National Standards Institute (ANSI).
The word COBOL is an acronym that stands for COmmon Business Oriented Language. As the the expanded acronym indicates, COBOL is designed for developing business, typically file-oriented, applications. It is not designed for writing systems programs. For instance you would not develop an operating system or a compiler using COBOL
Coding Sheet.
1-6 Page/line numbers - Optional (automatically assigned by compiler)
7 Continuity (-), Comment (*), Starting a new page (/), Debugging lines (D)
8-11 Column A -Division, Section, Paragraph, 01,77 declarations must begin here.
12-72 Column B -All the other declarations/statements begin here.
73-80 Identification field. It will be ignored by the compiler but visible in the source listing.
Language Structure.
Character Set :- Digits (0-9), Alphabets (A-Z), Space (b), Special Characters (+ - * / ( ) = $ ; " > < . ,) Word :- One or more characters- User defined or Reserved. Clause :- One or more words. It specifies an attribute for an entry. Statement :- One or more valid words and clauses. Sentence :- One or more statements terminated by a period. Paragraph :- One or more sentences. Section :- One or more paragraphs. Division :- One or more sections or paragraphs. Program :- Made up of four divisions. Divisions in COBOL. There are four divisions in a COBOL program and Data division is optional. 1. Identification Division. 2. Environment Division. 3. Data Division. 4. Procedure Division. Identification Division. This is the first division and the program is identified here. Paragraph PROGRAM-ID followed by user-defined name is mandatory. All other paragraphs are optional and used for documentation. The length of user-defined name for IBM COBOL is EIGHT. IDENTIFICATION DIVISION. PROGRAM-ID. PROGRAM NAME. AUTHOR. COMMENT ENTRY. INSTALLATION. COMMENT ENTRY. DATE-WRITTEN. COMMENT ENTRY. DATE-COMPILED. COMMENT ENTRY. SECURITY. COMMENT ENTRY. Security does not pertain to the operating system security, but the information that is passed to the user of the program about the security features of the program. Environment Division. Only machine dependant division of COBOL program. It supplies information about the hardware or computer equipment to be used on the program. When your program moves from one computer to another computer, the only section that may need to be changed is ENVIRONMENT division. Configuration Section. It supplies information concerning the computer on which the program will be compiled (SOURCE-COMPUTER) and executed (OBJECT-COMPUTER). It consists of three paragraphs - SOURCE COMPUTER, OBJECT-COMPUTER and SPECIAL-NAMES. This is OPTIONAL section from COBOL 85. SOURCE-COMPUTER. IBM-4381 (Computer and model # supplied by manufacturer) WITH DEBUGGING MODE clause specifies that the debugging lines in the program (statements coded with 'D' in column 7) are compiled. OBJECT-COMPUTER. IBM-4381 (Usually same as source computer) SPECIAL-NAMES. This paragraph is used to relate hardware names to user-specified mnemonic names. 1. Substitute character for currency sign. (CURRENCY SIGN IS litearal-1) 2. Comma can be used as decimal point. (DECIMAL-POINT IS COMMA) 3. Default collating sequence can be changed. It will be explained later . 4. New class can be defined using CLASS keyword. (CLASS DIGIT is "0" thru "9") Input-Output Section. It contains information regarding the files to be used in the program and it consists of two paragraphs FILE-CONTROL & I-O CONTROL. FILE CONTROL. Files used in the program are identified in this paragraph. I-O CONTROL. It specifies when check points to be taken and storage areas that are shared by different files. Data Division. Data division is used to define the data that need to be accessed by the program. It has three sections. FILE SECTION describes the record structure of the files. WORKING-STORAGE SECTION is used to for define intermediate variables. LINKAGE SECTION is used to access the external data. Ex: Data passed from other programs or from PARM of JCL. Literals, Constants, Identifier, 1. Literal is a constant and it can be numeric or non-numeric. 2. Numeric literal can hold 18 digits and non-numeric literal can hold 160 characters in it. (COBOL74 supports 120 characters only) 3. Literal stored in a named memory location is called as variable or identifier. 4. Figurative Constant is a COBOL reserved word representing frequently used constants. They are ZERO/ZEROS/ZEROES, QUOTE/QUOTES, SPACE/SPACES, ALL, HIGH-VALUE/HIGH-VALUES, LOW-VALUE/LOW-VALUES. Example: 01 WS-VAR1 PIC X(04) VALUE 'MUSA'. 'MUSA ' is a non-numeric literal. WS-VAR1 is a identifier or variable. Declaration of variable Level# $ {Variable/Filler} $ Picture clause $ Value clause $ Usage Clause $ Sync clause. Level# It specifies the hierarchy of data within a record. It can take a value from the set of integers between 01-49 or from one of the special level-numbers 66 77 88 01 level :- Specifies the record itself. It may be either a group item or an Elementary item. It must begin in Area A. 02-49 levels :- Specify group or elementary items within a record. Group level items must not have picture clause. 66 level :- Identify the items that contain the RENAMES clause. 77 level :- Identify independent data item. 88 level :- Condition names. Variable name and Qualifier Variable name can have 1-30 characters with at least one alphabet in it. Hyphen is the only allowed special character but it cannot be first or last letter of the name. Name should be unique within the record. If two variables with same name are there, then use OF qualifier of high level grouping to refer a variable uniquely. Ex: MOVE balance OF record-1 TO balance OF record-2. FILLER When the program is not intended to use selected fields in a record structure, define them as FILLER. FILLER items cannot be initialized or used in any operation of the procedure division. PICTURE Clause Describes the attributes of variable. Numeric 9 (Digit), V (Implied decimal point), S (Sign) Numeric Edited + (Plus Sign), - (Minus Sign), CR DB (Credit Debit Sign), '.' (Period), b (Blank), ','(comma), 0 (Zero), / (Slash) BLANK WHEN ZERO (Insert blank when data value is 0), Z (ZERO suppression), * (ASTERISK), $(Currency Sign) Non Numeric A (alphabet), B (Blank insertion Character), X(Alpha numeric), G(DBCS) Exclusive sets 1. + - CR DB 2. V '.' 3. $ + - Z * (But $ Can appear as first place and * as floating. $***.**) DBCS (Double Byte Character Set) is used in the applications that support large character sets. 16 bits are used for one character. Ex: Japanese language applications. Refreshing Basics Nibble :- 4 Bits is one nibble. In packed decimal, each nibble stores one digit. Byte :- 8 Bits is one byte. By default, every character is stored in one byte. Half word :- 16 bits or 2 bytes is one half word. (MVS) Full word :- 32 bits or 4 bytes is one full word. (MVS) Double word :- 64 bits or 8 bytes is one double word. (MVS) Usage Clause DISPLAY :- Default. Number of bytes required equals to the size of the data item. COMP :- Binary representation of data item. PIC clause can contain S and 9 only. S9(01) - S9(04) Half word. S9(05) - S9(09) Full word. S9(10) - S9(18) Double word. Most significant bit is ON if the number is negative. COMP-1 :- Single word floating point item. PIC Clause should not be specified. COMP-2 :- Double word floating-point item. PIC Clause should not be specified. COMP-3 :- Packed Decimal representation. Two digits are stored in each byte. Last nibble is for sign. (F for unsigned positive, C for signed positive and D for signed negative) Formula for Bytes: Integer ((n/2) + 1)) => n is number of 9s.
INDEX :- It is used for preserve the index value of an array. PIC Clause should not be specified.
VALUE Clause
It is used for initializing data items in the working storage section. Value of item must not exceed picture size. It cannot be specified for the items whose size is variable.

Syntax: VALUE IS literal.
VALUES ARE literal-1 THRU | THROUGH literal-2
VALUES ARE literal-1, literal-2
Literal can be numeric without quotes OR non-numeric within quotes OR figurative constant.
SIGN Clause
Syntax - SIGN IS (LEADING) SEPARATE CHARACTER (TRAILING).
It is applicable when the picture string contain 'S'. Default is TRAILING WITH NO SEPARATE CHARACTER. So 'S' doesn't take any space. It is stored along with last digit.
+1=A, +2=B, +3=C, +4=D, +5=E, +6=F, +7=G, +8=H, +9=I, -0=}, -1= J, -2= K, -3=L, -4=M, -5=N, -6=O, -7=P, -8=Q, -9=R
Number TRAILING SIGN (Default) LEADING SIGN LEADING SEPARATE
-125 12N J25 -125
+125 12E A25 +125
SYNC Clause and Slack Bytes
SYNC clause is specified with COMP, COMP-1 and COMP-2 items. These items are expected to start at half/full/double word boundaries for faster address resolution. SYNC clause does this but it may introduce slack bytes (unused bytes) before the binary item.

01 WS-TEST.
10 WS-VAR1 PIC X(02).
10 WS-VAR2 PIC S9(6) COMP SYNC.

Assumes WS-TEST starts at relative location 0 in the memory, WS-VAR1 occupies zero and first byte. WS-VAR2 is expected to start at second byte. As the comp item in the example needs one word and it is coded with SYNC clause, it will start only at the next word boundary that is 4th byte. So this introduces two slack bytes between WS-VAR1 and WS-VAR2.

REDEFINES
The REDEFINES clause allows you to use different data description entries to describe the same computer storage area. Redefining declaration should immediately follow the redefined item and should be done at the same level. Multiple redefinitions are possible. Size of redefined and redefining need not be the same.
Example:

01 WS-DATE PIC9(06).
01 WS-REDEF-DATE WS-DATE.
05 WS-YEAR PIC9(02).
05 WS-MON PIC9(02).
05 WS-DAY PIC9(02).
RENAMES
It is used for regrouping of elementary data items in a record. It should be declared at 66 level. It need not immediately follows the data item, which is being renamed. But all RENAMES entries associated with one logical record must immediately follow that record's last data description entry. RENAMES cannot be done for a 01, 77, 88 or another 66 entry.

01 WS-REPSONSE.
05 WS-CHAR143 PICX(03).
05 WS-CHAR4 PICX(04).
66 ADD-REPSONSE RENAMES WS-CHAR143.
CONDITION name
It is identified with special level '88'. A condition name specifies the value that a field can contain and used as abbreviation in condition checking.
01 SEX PIC X.
88 MALE VALUE '1'
88 FEMALE VALUE '2' '3'.
IF SEX=1 can also be coded as IF MALE in Procedure division.
'SET FEMALE TO TRUE ' moves value 2 to SEX.
If multiple values are coded on VALUE clause, the first value will be moved when it is set to true.
JUSTIFIED RIGHT
This clause can be specified with alphanumeric and alphabetic items for right justification. It cannot be used with 66 and 88 level items.
OCCURS Clause
OCCURS Clause is used to allocate physically contiguous memory locations to store the table values and access them with subscript or index. Detail explanation is given in Table Handling section.
LINKAGE SECTION
It is used to access the data that are external to the program. JCL can send maximum 100 characters to a program thru PARM. Linkage section MUST be coded with a half word binary field, prior to actual field. If length field is not coded, the first two bytes of the field coded in the linkage section will be filled with length and so there are chances of 2 bytes data truncation in the actual field.
01 LK-DATA.
05 LK-LENGTH PIC S9(04) COMP.
05 LK-VARIABLE PIC X(08).
Procedure Division.
This is the last division and business logic is coded here. It has user-defined sections and paragraphs. Section name should be unique within the program and paragraph name should be unique within the section.
Procedure division statements are broadly classified into following categories.
Statement Type Meaning
Imperative Direct the program to take a specific action.
Ex: MOVE ADD EXIT GO TO
Conditional Decide the truth or false of relational condition and based on it, execute different paths.
Ex: IF, EVALUATE
Compiler Directive Directs the compiler to take specific action during compilation.
Ex: COPY SKIP EJECT
Explicit Scope terminator Terminate the scope of conditional and imperative statements.
Ex: END-ADD END-IF END-EVALUATE
Implicit Scope terminator The period at the end of any sentence, terminates the scope of all previous statements not yet terminated.
MOVE Statement
It is used to transfer data between internal storage areas defined in either file section or working storage section.
Syntax:
MOVE identifier1/literal1/figurative-constant TO identifier2 (identifier3)
Multiple move statements can be separated using comma, semicolons, blanks or the keyword THEN.
Numeric move rules:
A numeric or numeric-edited item receives data in such a way that the decimal point is aligned first and then filling of the receiving field takes place. Unfilled positions are filled with zero. Zero suppression or insertion of editing symbols takes places according to the rules of editing pictures. If the receiving field width is smaller than sending field then excess digits, to the left and/or to the right of the decimal point are truncated.
Alphanumeric Move Rules:
Alphabetic, alphanumeric or alphanumeric-edited data field receives the data from left to right. Any unfilled field of the receiving filed is filled with spaces. When the length of receiving field is shorter than that of sending field, then receiving field accepts characters from left to right until it is filled. The unaccomodated characters on the right of the sending field are truncated. When an alphanumeric field is moved to a numeric or numeric-edited field, the item is moved as if it were in an unsigned numeric integer mode. CORRESPONDING can be used to transfer data between items of the same names belonging to different group-items by specifying the names of group-items to which they belong.
MOVE CORRESPONDING group-1 TO group-2
Group Move rule
When MOVE statement is used to move information at group level, the movement of data takes place as if both sending and receiving fields are specified as alphanumeric items. This is regardless of the description of the elementary items constituting the group item.
Samples for understanding MOVE statement (MOVE A TO B)
Picture of A Value of A Picture of B Value of B after Move
PIC 99V99 12.35 PIC 999V99 012.35
PIC 99V99 12.35 PIC 9999V9999 0012.3500
PIC99V999 12.345 PIC9V99 2.34
PIC9(05)V9(03) 54321.543 PIC 9(03)V9(03) 321.543
PIC9(04)V9(02) 23.24 PICZZZ99.9 23.2
PIC99V99 00.34 PIC$$$.99 $.34
PICX(04) MUSA XBXBXB M U S
ARITHMETIC VERBS
All the possible arithmetic operations in COBOL using ADD, SUBTRACT, MULTIPLY and DIVIDE are given below:
Arithmetic Operation A B C D
ADD A TO B A A+B
ADD A B C TO D A B C A+B+C+D
ADD A B C GIVING D A B C A+B+C
ADD A TO B C A A+B A+C
SUBTRACT A FROM B A B-A
SUBTRACT A B FROM C A B C-(A+B)
SUBTRACT A B FROM C GIVING D A B C C-(A+B)
MULTIPLY A BY B A A*B
MULTIPLY A BY B GIVING C A B A*B
DIVIDE A INTO B A B/A
DIVIDE A INTO B GIVING C A B B/A
DIVIDE A BY B GIVING C A B A/B
DIVIDE A INTO B GIVING C REMAINDER D A B Integer (B/A) Integer remainder
GIVING is used in the following cases:
1.To retain the values of operands participating in the operation.
2.The resultant value of operation exceeds any of the operand size.
ROUNDED option
With ROUNDED option, the computer will always round the result to the PICTURE clause specification of the receiving field. It is usually coded after the field to be rounded. It is prefixed with REMAINDER keyword ONLY in DIVIDE operation.
ADD A B GIVING C ROUNDED.
Caution: Don't use for intermediate computation.

ON SIZE ERROR
If A=20 (PIC 9(02)) and B=90 (PIC 9(02)), ADD A TO B will result 10 in B where the expected value in B is 110. ON SIZE ERROR clause is coded to trap such size errors in arithmetic operation.
If this is coded with arithmetic statement, any operation that ended with SIZE error will not be carried out but the statement follows ON SIZE ERROR will be executed.
ADD A TO B ON SIZE ERROR DISPLAY 'ERROR!'.
COMPUTE
Complex arithmetic operations can be carried out using COMPUTE statement. We can use arithmetic symbols than keywords and so it is simple and easy to code.
+ For ADD, - for SUBTRACT, * for MULTIPLY, / for DIVIDE and ** for exponentiation.
Rule: Left to right -
1.Parentheses
2.Exponentiation
3.Multiplication and Division
4.Addition and Subtraction
Caution: When ROUNDED is coded with COMPUTE, some compiler will do rounding for every arithmetic operation and so the final result would not be precise. 77 A PIC 999 VALUE 10
COMPUTE A ROUNDED = (A+2.95) *10.99
Result: (ROUNDED(ROUNDED(12.95) * ROUNDED(10.99)) =120 or ROUNDED(142.3205) = 142 So the result can be 120 or 142.
Be cautious when using ROUNDED keyword with COMPUTE statement.
All arithmetic operators have their own explicit scope terminators. (END-ADD, END-SUBTRACT, END-MULTIPLY, END-DIVIDE, END-COMPUTE). It is suggested to use them.
CORRESPONDING is available for ADD and SUBTRACT only.
INITIALIZE
VALUE clause is used to initialize the data items in the working storage section whereas INITIALIZE is used to initialize the data items in the procedure division. INITIALIZE sets the alphabetic, alphanumeric and alphanumeric-edited items to SPACES and numeric and numeric-edited items to ZERO. This can be overridden by REPLACING option of INITIALIZE. FILLER, OCCURS DEPENDING ON items are not affected.
Syntax: INITIALIZE identifier-1 REPLACING (ALPHABETIC/ALPHANUMERIC/ALPHA-NUMERIC-EDITED NUMERIC/NUMERIC-EDITED) DATA BY (identifier-2 /Literal-2)
ACCEPT
ACCEPT can transfer data from input device or system information contain in the reserved data items like DATE, TIME, DAY.
ACCEPT WS-VAR1 (FROM DATE/TIME/DAY/OTHER SYSTEM VARS).
If FROM Clause is not coded, then the data is read from terminal. At the time of execution, batch program will ABEND if there is no in-stream data from JCL and there is no FROM clause in the ACCEPT clause. DATE option returns six digit current date in YYYYMMDD
DAY returns 5 digit current date in YYDDD
TIME returns 8 digit RUN TIME in HHMMSSTT
DAY-OF-WEEK returns single digit whose value can be 1-7 (Monday-Sunday respectively)

DISPLAY
It is used to display data. By default display messages are routed to SYSOUT.
Syntax: DISPLAY identifier1| literal1 (UPON mnemonic name)
STOP RUN, EXIT PROGRAM & GO BACK
STOP RUN is the last executable statement of the main program. It returns control back to OS.
EXIT PROGRAM is the last executable statement of sub-program. It returns control back to main program.
GOBACK can be coded in main program as well as sub-program as the last statement. It just gives the control back from where it received the control.
Collating Sequence
There are two famous Collating Sequence available in computers. IBM and IBM Compatible machine use EBCDIC collating sequence whereas most micro and many mainframe systems use ASCII collating sequence. The result of arithmetic and alphabetic comparison would be same in both collating sequences whereas the same is not true for alphanumeric comparison
EBCDIC (Ascending Order) ASCII (Ascending Order)
Special Characters Special Characters
a-z 0-9
A-Z A-Z
0-9 a-z
Default collating sequence can be overridden by an entry in OBJECT-COMPUTER and SPECIAL NAMES paragraphs.
1. Code the PROGRAM COLLATING SEQUENCE Clause in the Object computer paragraph. PROGRAM COLLATING SEQUENCE IS alphabet-name
2. Map the alphabet-name in the SPECIAL-NAMES paragraph as follows:
ALPHABET alphabet-name is STANDARD-1 | NATIVE
NATIVE stands for computer's own collating sequence whereas STANDARD-1 stands for ASCII collating sequence.
IF/THEN/ELSE/END-IF
The most famous decision making statement in all language is 'IF'. The syntax of IF statement is given below: IF can be coded without any ELSE statement. THEN is a noise word and it is optional.
If ORs & ANDs are used in the same sentence, ANDs are evaluated first from left to right, followed by ORs.
This rule can be overridden by using parentheses. The permitted relation conditions are =, <, >, <=, >=, <>
CONTINUE is no operation statement. The control is just passed to next STATEMENT.
NEXT SENTENCE passes the control to the next SENTENCE.
If you forgot the difference between statement and sentence, refer the first page. It is advised to use END-IF, explicit scope terminator for the IF statements than period, implicit scope terminator.
IF condition1 AND condition2 THEN
Statement-Block-1
ELSE
IF condition3 THEN
CONTINUE
ELSE
IF condition4 THEN
Statement-Block-2
ELSE
NEXT SENTENCE
END-IF
END-IF
END-IF
Statement-Block-2 will be executed only when condition 1, 2 and 4 are TRUE and condition 3 is FALSE.
Implied operand: In compound conditions, it is not always necessary to specify both operands for each condition.
IF TOTAL=7 or 8 is acceptable. Here TOTAL=8 is implied operation.
SIGN test and CLASS test
SIGN test is used to check the sign of a data item. It can be done as follows -
IF identifier is POSITIVE/NEGATIVE/ZERO
CLASS test is used to check the content of data item against pre-defined range of values. It can be done as follows -
IF identifier is NUMERIC/ALPHABETIC/ALPHABETIC-HIGHER/ALPHABETIC-LOWER
You can define your own classes in the special names paragraph. We have defined a class DIGIT in our special names paragraph. It can be used in the following way. IF identifier is DIGIT
Negated conditions.
Any simple, relational, class, sign test can be negated using NOT.
But it is not always true that NOT NEGATIVE is equal to POSITIVE. (Example ZERO)
EVALUATE
With COBOL85, we use the EVALUATE verb to implement the case structure of other languages. Multiple IF statements can be efficiently and effectively replaced with EVALUATE statement. After the execution of one of the when clauses, the control is automatically come to the next statement after the END-EVALUATE. Any complex condition can be given in the WHEN clause. Break statement is not needed, as it is so in other languages.
General Syntax


EVALUATE subject-1 (ALSO subject2..)
WHEN object-1 (ALSO object2..)
WHEN object-3 (ALSO object4..)
WHEN OTHER imperative statement
END-EVALUATE.
1.Number of Subjects in EVALUATE clause should be equal to number of objects in every WHEN clause.
2.Subject can be variable, expression or the keyword TRUE/ FLASE and respectively objects can be values, TRUE/FALSE or any condition.
3.If none of the WHEN condition is satisfied, then WHEN OTHER path will be executed.
Sample
EVALUATE SQLCODE ALSO TRUE
WHEN 100 ALSO A=B imperative statement
WHEN -305 ALSO (A/C=4) imperative statement
WHEN OTHER imperative statement
END-EVALUATE.
PERFORM STATEMENTS
PERFORM will be useful when you want to execute a set of statements in multiple places of the program. Write all the statements in one paragraph and invoke it using PERFORM wherever needed. Once the paragraph is executed, the control comes back to next statement following the PERFORM.

1.SIMPLE PERFORM.
PERFORM PARA-1.
DISPLAY 'PARA-1 executed'
STOP RUN.
PARA-1.
Statement1.
Statement2.
It executes all the instructions coded in PARA-1 and then transfers the control to the next instruction in sequence.
2. INLINE PERFORM.
When set of statements are used only in one place then we can group all of them within PERFORM END-PERFORM structure. This is called INLINE PERFORM. This is equal to DO..END structure of other languages.

PERFORM
ADD A TO B
MULTIPLE B BY C
DISPLAY 'VALUE OF A+B*C ' C
END-PERFORM
3. PERFORM PARA-1 THRU PARA-N.
All the paragraphs between PARA-1 and PARA-N are executed once.
4. PERFORM PARA-1 THRU PARA-N UNTIL condition(s).
The identifiers used in the UNTIL condition(s) must be altered within the paragraph(s) being performed; otherwise the paragraphs will be performed indefinitely. If the condition in the UNTIL clause is met at first time of execution, then named paragraph(s) will not be executed at all.
5. PERFORM PARA-1 THRU PARA-N N TIMES.
N can be literal defined as numeric item in working storage or hard coded constant.
6. PERFORM PARA-1 THRU PARA-N VARYING identifier1
FROM identifier2 BY identifier3 UNTIL condition(s) Initialize identifier1 with identifier2 and test the condition(s). If the condition is false execute the statements in PARA-1 thru PARA-N and increment identifier1 BY identifier3 and check the condition(s) again. If the condition is again false, repeat this process till the condition is satisfied.
7.PERFORM PARA-1 WITH TEST BEFORE/AFTER UNTIL condition(s).
With TEST BEFORE, Condition is checked first and if it found false, then PARA-1 is executed and this is the default. (Functions like DO- WHILE) With TEST AFTER, PARA-1 is executed once and then the condition is checked. (Functions like DO-UNTIL)
EXIT statement.
COBOL reserved word that performs NOTHING. It is used as a single statement in a paragraph that indicate the end of paragraph(s) execution. EXIT must be the only statement in a paragraph in COBOL74 whereas it can be used with other statements in COBOL85.
GO TO Usage:
In a structured top-down programming GO TO is not preferable. It offers permanent control transfer to another paragraph and the chances of logic errors is much greater with GO TO than PERFORM. The readability of the program will also be badly affected.
But still GO TO can be used within the paragraphs being performed. i.e. When using the THRU option of PERFORM statement, branches or GO TO statements, are permitted as long as they are within the range of named paragraphs.
PERFORM 100-STEP1 THRU STEP-4
100-STEP-1.
ADD A TO B GIVING C.
IF D = ZERO DISPLAY 'MULTIPLICATION NOT DONE'
GO TO 300-STEP3
END-IF.
200-STEP-2.
MULTIPLY C BY D.
300-STEP-3.
DISPLAY 'VALUE OF C:' C.
Here GO TO used within the range of PERFORM. This kind of Controlled GO TO is fine with structured programming also!
TABLES
An OCCURS clause is used to indicate the repeated occurrences of items of the same format in a structure. OCCURS clause is not valid for 01, 77, 88 levels.
It can be defined as elementary or group item. Initialization of large table occurrences with specific values are usually done using perform loops in procedure division. Simple tables can be initialized in the following way.
01 WEEK-ARRAY VALUE 'MONTUEWEDTHUFRISATSUN'.
05 WS-WEEK-DAYS OCCURS 7 TIMES PIC X(03).
Dynamic array is the array whose size is decided during runtime just before the access of first element of the array.
01 WS-MONTH-DAY-CAL.
05 WS-DAYS OCCURS 31 TIMES DEPENDING ON WS-OCCURENCE.
IF MONTH = 'FEB' MOVE '28' to WS-OCCURRENCE.
Array Items can be accessed using INDEX or subscript and the difference between them are listed in the table. Relative subscripts and relative indexes are supported only in COBOL85. Literals used in relative subscripting/indexing must be an unsigned integer.
ADD WS-SAL(SUB) WS-SAL(SUB + 1) TO WS-SAL(SUB + 2).

Sl # Subscript Index
1 Working Storage item Internal Item-No need to declare it.
2 It means occurrence It means displacement
3 Occurrence, in turn translated to displacement to access elements and so slower than INDEX access. Faster and efficient.
4 It can be used in any arithmetic operations or for display. It cannot be used for arithmetic operation or for display purpose.
5 Subscripts can be modified by any arithmetic statement. INDEX can only be modified with SET, SEARCH and PERFORM statements.
Sometimes, you may face a question like how to randomly access the information in the sequential file of 50 records that contains all the designation and the respective lower and higher salary information.
Obviously, OS does not allow you to randomly access the sequence file. You have to do by yourself and the best way is, load the file into a working storage table in the first section of the program and then access as you wish.
The table look-up can be done in two ways.
-Sequential search.
-Binary search.

Sequential SEARCH
During SERIAL SEARCH, the first entry of the table is searched. If the condition is met, the table look-up is completed. If the condition is not met, then index or subscript is incremented by one and the next entry is searched and the process continues until a match is found or the table has been completely searched.
SET indexname-1 TO 1.
SEARCH identifier-1 AT END display 'match not found:'
WHEN condition-1 imperative statement-1 /NEXT SENTENCE
WHEN condition-2 imperative statement-2 /NEXT SENTENCE
END-SEARCH
Identifier-1 should be OCCURS item and not 01 item.
Condition-1, Condition-2 compares an input field or search argument with a table argument.
Though AT END Clause is optional, it is highly recommended to code that. Because if it is not coded and element looking for is not found, then the control simply comes to the next statement after SEARCH where an invalid table item can be referred and that may lead to incorrect results / abnormal ends.
SET statement Syntax:
SET index-name-1 TO/UP BY/DOWN BY integer-1.
Binary SEARCH
When the size of the table is large and it is arranged in some sequence -either ascending or descending on search field, then BINARY SEARCH would be the efficient method.
SEARCH ALL identifier-1 AT END imperative-statement-1
WHEN dataname-1 = identifier-2/literal-1/arithmetic expression-1
AND dataname-2 = identifier-3/literal-2/arithmetic expression-2
END-SEARCH.
Identifier-2 and identifier-3 are subscripted items and dataname-1 and dataname-2 are working storage items that are not subscripted.
Compare the item to be searched with the item at the center. If it matches fine, else repeat the process with the left or right half depending on where the item lies.
Sl # Sequential SEARCH Binary SEARCH
1 SEARCH SEARCH ALL
2 Table should have INDEX. Table should have INDEX.
3 Table need not be in SORTED order. Table should be in sorted order of the searching argument. There should be ASCENDING/DESCENDING Clause.
4 Multiple WHEN conditions can be coded. Only one WHEN condition can be coded.
5 Any logical comparison is possible. Only = is possible. Only AND is possible in compound conditions.
6 Index should be set to 1 before using SEARCH Index need not be set to 1 before SEARCH ALL.
7 Prefer when the table size is small Prefer when the table size is significantly large.
Multi Dimensional Arrays
COBOL74 supports array of maximum of three dimensions whereas COBOL85 supports up to seven dimensions. The lowest- level OCCURS data-name or an item subordinate to it is used to access an entry in the array or the table.
If we use SEARCH for accessing multi-dimension table, then INDEXED BY must be used on all OCCURS levels. Expanded nested perform is available for processing multi level tables. The syntax of this perform is given below:
PERFORM para-1 thru para-n VARYING index-1 from 1 BY 1 UNTIL index-1 > size- of- outer-occurs AFTER VARYING index-2 from 1 by 1 until index-2 > size of inner occurs.
SEARCH example for multi level tables:

01 EMP-TABLE.
05 DEPTNUMBER OCCURS 10 TIMES INDEXED BY I1.
10 EMP-DETAIL OCCURS 50 TIMES INDEXED BY I2.
15 EMP-NUMBER PIC 9(04).
15 EMP-SALARY PIC 9(05).
77 EMPNUMBER-IN PIC 9(04) VALUE '2052'.
PERFORM 100-SEARCH-EMP-SAL VARYING I1 FROM 1 BY 1
UNTIL I1 > 10 OR WS-FOUND
100-SEARCH-EMP-SAL.
SET I2 TO I.
SEARCH EMP-DETAIL AT END DISPLAY 'NOT FOUND'. == > Lowest Occurs
WHEN EMPNUMBER-IN = EMP-NUMBER(I1,I2).
DISPLAY 'SALARY IS:' EMP-SALARY(I1,I2).
SET WS-FOUND TO TRUE. == > Search ends
END-SEARCH.
NESTED PROGRAMS, GLOBAL, EXTERNAL
One program may contain other program(s). The contained program(s) may themselves contain yet other program(s). All the contained and containing programs should end with END PROGRAM statement. PGMB is nested a program in the example below:
Example: IDENTIFICATION DIVISION.
PROGRAM-ID. PGMA
.....
IDENTIFICATION DIVISION.
PROGRAM-ID. PGMB
.....
END PROGRAM PGMB.
....
END PROGRAM PGMA.
If you want access any working storage variable of PGMA in PGMB, then declare them with the clause 'IS GLOBAL' in PGMA. If you want to access any working storage variable of PGMB in PGMA, declare them with the clause 'IS EXTERNAL' in PGMB. Nested Programs are supported only in COBOL85.
If there is a program PGMC inside PGMB, it cannot be called from PGMA unless it's program id is qualified with keyword COMMON.
SORT and MERGE
The programming SORT is called as internal sort whereas the sort in JCL is called external sort. If you want to manipulate the data before feeding to sort, prefer internal sort. In all other cases, external sort is the good choice. Internal sort, in turn invokes the SORT product of your installation. (DFSORT). In the run JCL, allocate at least three sort work files. (SORT-WKnn => nn can be 00-99).
FASTSRT compiler option makes the DFSORT to do all file I-O operation than your COBOL program. It would significantly improve the performance. The result of the SORT can be checked in SORT-RETURN register. If the sort is successful, the value will be 0 else 16.
Syntax:
SORT SORTFILE ON ASCENDING /DESCENDING KEY sd-key-1 sd-key2
USING file1 file2 / INPUT PROCEDURE IS section-1
GIVING file3 / OUTPUT PROCEDURE is section-2
END-SORT
File1, File2 are to-be-sorted input files and File3 is sorted-output file and all of them are defined in FD.SORTFILE is Disk SORT Work file that is defined at SD. It should not be explicitly opened or closed.
INPUT PROCEDURE and USING are mutually exclusive. If USING is used, then file1 and files should not be opened or READ explicitly. If INPUT PROCEDURE is used then File1 and file2 need to be OPENed and READ the records one by one until end of the file and pass the required records to sort-work-file using the command RELEASE.
Syntax:
RELEASE sort-work-record from input-file-record.
OUTPUT Procedure and GIVING are mutually exclusive. If GIVING is used, then file3 should not be opened or WRITE explicitly. If OUTPUT procedure is used, then File3 should be OPENed and the required records from sort work file should be RETURNed to it. Once AT END is reached for sort-work-file, close the output file.
Syntax:
RETURN sort-work-file-name AT END imperative statement.
INPUT PROCEDURE Vs OUTPUT PROCEDURE
Sometimes it would be more efficient to process data before it is sorted, whereas other times it is more efficient to process after it is sorted. If we intend to eliminate more records, then it would be better preprocess them before feeding to SORT. If we want to eliminate all the records having spaces in the key field then it would be efficient if we eliminate them after sorting. Because the records with blank key comes first after sorting.
MERGE
It is same as sort. USING is mandatory. There should be minimum two files in USING.
MERGE Sort-work-file ON ASCENDING KEY dataname1 dataname2
USING file1 file2
GIVING file3 / OUTPUT PROCEDURE is section-1
END-MERGE
Program sort registers (and its equivalent DFSORT parameter/meaning)
SORT-FILE-SIZE (FILSZ), SORT-CORE-SIZE (RESINV), SORT-MSG(MSGDDN)
SORT-MODE-SIZE (SMS=nnnnn)
SORT-RETURN(return-code of sort) and
SORT-CONTROL (Names the file of control card - default is IGZSRTCD)
STRING MANIPULATION
A string refers to a sequence of characters. String manipulation operations include finding a particular character/sub-string in a string, replacing particular character/sub-string in a string, concatenating strings and segmenting strings. All these functions are handled by three verbs INSPECT, STRING and UNSTRING in COBOL. EXAMINE is the obsolete version of INSPECT supported in COBOL74.
INSPECT- FOR COUNTING
It is used to tally the occurrence of a single character or groups of characters in a data field.
INSPECT identifier-1 TALLYING identifier-2 FOR ALL/LEADING literal-1|identifier-3 [BEFORE|AFTER INITIAL identifier-4|literal-2] - Optional.
INSPECT identifier-1 TALLYING identifier-2 FOR CHARACTERS [BEFORE|AFTER INITIAL identifier-4|literal-2] - Optional.
Main String is identifier-1 and count is stored in identifier-2. Literal-1 or Identifier-3 is a character or group-of-characters you are looking in the main-string. INSPECT further qualifies the search with BEFORE and AFTER of the initial occurrence of identifier-4 or literal-2.
Example:
WS-NAME - 'MUTHU SARAVANA SURYA CHANDRA DEVI'
INSPECT WS-NAME TALLYING WS-COUNT ALL 'S'
BEFORE INITIAL 'SARAVANA' AFTER INITIAL 'CHANDRA'
END-INSPECT
Result:
WS-COUNT contains - 1
INSPECT- FOR REPLACING
It is used to replace the occurrence of a single character or groups of characters in a data field.
INSPECT identifier-1 REPLACING ALL|LEADING literal-1|identifier-2 BY identifier-3|literal-2 [BEFORE|AFTER INITIAL identifier-4|literal-2] - Optional.
INSPECT identifier-1 REPLCING CHARACTERS BY identifier-2 BEFORE|AFTER INITIAL identifier-3|literal-1
INSPECT-FOR COUNTING AND REPLACING It is a combination of the above two methods. INSPECT identifier-1 TALLYING (tallying part ) REPLACING (replacing part)
STRING
STRING command is used to concatenate one or more strings.
Syntax:
STRING identifier-1 / literal-1, identifier-2/ literal-2 DELIMITED BY (identifier-3/literal-3/SIZE) INTO identifier-4 END-STRING.
01 VAR1 PIC X(10) VALUE 'MUTHU '
01 VAR2 PIC X(10) VALUE 'SARA '
01 VAR2 PIC X(20).
To get display 'MUTHU,SARA'
STRING VAR1 DELIMITED BY ' ' ',' DELIMITED BY SIZE VAR2 DELIMITED BY ' ' INTO VAR3 END-STRING.
The receiving field must be an elementary data item with no editing symbols and JUST RIGHT clause.
With STRING statement, specific characters of a string can be replaced whereas MOVE replaces the full string.
01 AGE-OUT PIC X(12) VALUE '12 YEARS OLD'.
STRING '18' DELIMITED BY SIZE INTO AGE-OUT. => 18 YEARS OLD.

Reference Modification - equivalent of SUBSTR
'Reference modification' is used to retrieve or overwrite a sub-string of a string. ':' is known as reference modification operator.
Syntax:
String (Starting-Position:Length)
MOVE '18' TO AGE-OUT(1:2) does the same as what we did with STRING command.
When it is used in array elements, the syntax is Array-element (occurrence) (Starting-Position:Length)
UNSTRING
UNSTRING command is used to split one string to many strings.
Syntax:
UNSTRING identifier-1 [DELIMITED BY (ALL/) identifier2/literal1 [,OR (ALL/) (identifier-3/literal-2),..]] INTO identifier-4 [,DELIMITER IN identifier-5, COUNT IN identifier-6] [,identifier-7 [,DELIMITER IN identifier-8, COUNT IN identifier-9]
01 WS-DATA PIC X(12) VALUE '10/200/300/1'.
UNSTRING WS-DATA DELIMITED BY '/'
INTO WS-FLD1 DELIMITER IN WS-D1 COUNT IN WS-C1
WS-FLD2 DELIMITER IN WS-D2 COUNT IN WS-C2
WS-FLD3 DELIMITER IN WS-D3 COUNT IN WS-C3
END-UNSTRING.
Result:
WS-FLD1 = 10 WS-FLD2 =200 WS-FLD3=300 WS-C1 = 2 WS-C2=3 WS-C3=3 WS-D1 = '/' WS-D2='/' WS-D3 ='/'
ON OVERFLOW can be coded with STRING and UNSTRING. If there is STRING truncation then the imperative statements followed ON OVERFLOW will be executed.
COPY Statement
A COPY statement is used to bring a series of prewritten COBOL entries that have been stored in library, into a program.
1.Common routines like error routine, date validation routine are coded in a library and bring into the program by COPY.
2. Master files are used in multiple programs. Their layout can be placed in one copybook and be placed wherever the files are used. It promotes program standardization since all the programs share the same layout and the same data names.
This reduces coding and debugging time. Change in layout needs change in copybook only. It is enough if we just recompile the program for making the new copy effective.
Syntax:
COPY copybook-name [(OF/IN) library name]
[REPLACING string-to-be-replaced BY replacing-string]
Copybooks are stored as members in PDS library and during compilation time, they are included into the program. By default, the copybook library is SYSLIB and it can be changed using IN or OF of COPY statement.
Copybooks can be used in the following paragraphs.
SOURCE-COMPUTER, OBJECT-COMPUTER, SPECIAL-NAMES, FILE-CONTROL, IO-CONTROL, FD SECTION, PARAGRAPHS IN PROCEDURE DIVISION.
If the same copybook is used more than once in the program, then there will be "duplicate data declaration" error during compilation, as all the fields are declared twice. In this case, one copybook can be used with REPLACING verb to replace high-level qualifier of the all the variables with another qualifier.
Example:
COPY CUSTOMER REPLACING 'CUST1-' BY 'CUST2-'.
Delimiter '= =' should be used for replacing pseudo texts. The replacing option does not alter the prewritten entries in the library; the changes are made to the user's source program only.
CALL statement (Sub-Programs)
When a specific functionality need to be performed in more than one program, it is best to write them separately and call them into each program. Sub Programs can be written in any programming language. They are typically written in a language best suited to the specific task required and thus provide greater flexibility.
Main Program Changes:
CALL statement is used for executing the sub-program from the main program. A sample of CALL statement is given below:
CALL 'PGM2' USING BY REFERENCE WS-VAR1, BY CONTENT WS-VAR2.
PGM2 is called here. WS-VAR1 and WS-VAR2 are working storage items.
WS-VAR1 is passed by reference. WS-VAR2 is passed by Content. BY REFERENCE is default in COBOL and need not be coded. BY CONTENT LENGTH phrase permits the length of data item to be passed to a called program.
Sub-Program Changes:
WS-VAR1 and WS-VAR2 are working storage items of main program.
As we have already mentioned, the linkage section is used for accessing external elements. As these working storage items are owned by main program, to access them in the sub-program, we need to define them in the linkage section.
LINKAGE SECTION.
01 LINKAGE SECTION.
05 LK-VAR1 PIC 9(04).
05 LK-VAR2 PIC 9(04).
In addition to define them in linkage section, the procedure division should be coded with these data items for address-ability.

PROCEDURE DIVISION USING LK-VAR1,LK-VAR2
There is a one-one correspondence between passed elements and received elements (Call using, linkage and procedure division using) BY POSITION. This implies that the name of the identifiers in the called and calling program need not be the same (WS-VAR1 & LK-VAR1) but the number of elements and picture clause should be same.
The last statement of your sub-program should be EXIT PROGRAM. This returns the control back to main program. GOBACK can also be coded instead of EXIT PROGRAM but not STOP RUN. EXIT PROGRAM should be the only statement in a paragraph in COBOL74 whereas it can be coded along with other statements in a paragraph in COBOL85.
PROGRAM-ID. IS INITIAL PROGRAM.
If IS INITIAL PROGRAM is coded along with program-id of sub program, then the program will be in initial stage every time it is called (COBOL85 feature). Alternatively CANCEL issued after CALL, will set the sub-program to initial state.
If the sub program is modified then it needs to be recompiled. The need for main program recompilation is decided by the compiler option used for the main program. If the DYNAM compiler is used, then there is no need to recompile the main program. The modified subroutine will be in effect during the run. NODYNAM is default that expects the main program recompilation.
Difference between Pass-by-reference and Pass-by-content

Sl # Passl By Reference Pass By Content
1 CALL 'sub1' USING BY REFERENCE WS-VAR1 CALL 'sub1' USING BY CONTENT WS-VAR1 (BY CONTENT keyword is needed)
2 It is default in COBOL. BY REFERENCE is not needed. BY CONTENT key word is mandatory to pass an element by value.
3 Address of WS-VAR1 is passed Value of WS-VAR1 is passed
4 The sub-program modifications on the passed elements are visible in the main program. The sub-program modifications on the passed elements are local to that sub-program and not visible in the main program.
Difference between Static Call and Dynamic Call
Sl # STATIC Call DYNAMIC Call
1 Identified by Call literal. Ex: CALL 'PGM1'. Identified by Call variable and the variable should be populated at run time. 01 WS-PGM PIC X(08). Move 'PGM1' to WS-PGM CALL WS-PGM
2 Default Compiler option is NODYNAM and so all the literal calls are considered as static calls. If you want convert the literal calls into DYNAMIC, the program should be compiled with DYNAM option. By default, call variables and any un-resolved calls are considered as dynamic.
3 If the subprogram undergoes change, sub program and main program need to be recompiled. If the subprogram undergoes change, recompilation of subprogram is enough.
4 Sub modules are link edited with main module. Sub modules are picked up during run time from the load library.
5 Size of load module will be large Size of load module will be less.
6 Fast Slow compared to Static call.
7 Less flexible. More flexible.
8 Sub-program will not be in initial stage the next time it is called unless you explicitly use INITIAL or you do a CANCEL after each call. Program will be in initial state every time it is called.
INTRINSIC FUNCTIONS:
LENGTH :- Returns the length of the PIC clause. Used for finding length of group item that spanned across multiple levels.
MAX :- Returns the content of the argument that contains the maximum value
MIN :- Returns the content of the argument that contains the minimum value
NUMVAL :- Returns the numeric value represented by an alphanumeric character string specified in the argument.
NUMVAL-C :- Same as NUMVAL but currency and decimal points are ignored during conversion.
CURRENT DATE :- Returns 21 Chars alphanumeric value – YYYYMMDDHHMMSSnnnnnn
INTEGER OF DATE :- Returns INTEGER equivalent of Gregorian date passed.
INTEGER OF DAY :- Returns INTEGER equivalent of Julian date passed.
DATE OF INTEGER :- Returns Gregorian date for the integer passed.
DAY OF INTEGER :- Returns Julian date for the integer passed.
Note: FUNCTION INTEGER OF DATE (01-01-1601) returns 1.
FILE HANDLING
A data file is collection of relevant records and a record is collection of relevant fields. The file handling in COBOL program involves five steps.
Steps in file-handing
1.Allocation: The files used in the program should be declared in FILE-CONTROL paragraph of environment division. The mapping with JCL DDNAME is done here. The file is allocated to your program by this statement.
2.Definition. The layout of the file and its attributes are defined in the FILE SECTION of DATA DIVISION.
3.Open: Dataset is connected/readied to your program using OPEN statement. The mode of OPEN decides the operation allowed and the initial pointer in the dataset. For example, EXTEND mode allows only write access and the pointer is kept on the end of file to append.
4.Process: Process the file as per requirement, using the I-O statements provided by COBOL. (READ, WRITE, REWRITE and DELETE)
5. Close: After the processing, close the file to disconnect it from the program.
Allocation of file - SELECT Statement
(ENVIRONMENT-> INPUT-OUTPUT-> FILE-CONTROL)
SELECT [OPTIONAL] FILENAME ASSIGN to DDNAME :- ALL Files
ORGANIZATION IS SEQUENTIAL/INDEXED/RELATIVE :- ALL Files
ACCESS IS SEQUNETIAL/RANDOM/DYNAMIC :- ALL Files
RECORD KEY IS FILE-KEY1 :- KSDS
RELATIVE KEY IS WS-RRN :- RRDS
ALTERNARE RECORD KEY IS FILE-KEY2 WITH DUPLICATES :- KSDS
ALTERNARE RECORD KEY IS FILE-KEY3 WITHOUT DUPLICATES :- AIX
FILE STATUS IS WS-FILE-STAT1 :- ALL Files
[,WS-FILE-STAT2] :- VSAM Files
SELECT Statement- OPTIONAL Clause
This can be coded only for input files. If OPTIONAL is not coded, then the input file is expected to present in JCL. If not, an execution error will occur. If OPTIONAL is coded, then if the file is not mapped in JCL, it is considered as empty file and the first read results end of file. The file can also be dynamically allocated instead of static allocation in JCL.
SELECT Statement- ASSIGN TO
FILENAME is the logical name used inside the program and DDNAME is the logical name in the JCL, mapped with physical dataset. DDNAME can be prefixed with 'S-' to indicate QSAM file, '-AS' to indicate ESDS file and with no prefix to indicate KSDS/RRDS file.
JCL Step executing the program should have a dataset with DDNAME as label
//DDNAME DD DSN=BPMAIN.EMPLOYEE.DATA, DISP=SHR

SELECT Statement-ORGANIZATION
It can be SEQUENTIAL (PS or VSAM ESDS), INDEXED (VSAM KSDS), RELATIVE (VSAM RRDS). Default is Sequential.
SELECT Statement-ACCESS MODE
SEQUENTIAL.
It is default access mode and it is used to access the records ONLY in sequential order. To read 100th record, first 99 records need to be read and skipped.
RANDOM.
Records can be randomly accessed in the program using the primary/alternate key of indexed file organization or relative record number of relative organization.100th record can directly be read after getting the address of the record from the INDEX part for INDEXED files.100th record can directly be read for RELATIVE files even without any index.
DYNAMIC.
It is mixed access mode where the file can be accessed in random as well as sequential mode in the program. Example: Reading the details of all the employees between 1000-2000. First randomly access 1000th employee record, then read sequentially till 2000th employee record. START and READ NEXT commands are used for this purpose in the procedure division.
SELECT Statement-RECORD KEY IS
It is primary key of VSAM KSDS file. It should be unique and part of indexed record structure.
SELECT Statement-ALTERNATE RECORD KEY IS
This phrase is used for KSDS files defined with AIX. Add the clause WITH DUPLICATES if the AIX is defined with duplicates. Referring to VSAM basics, every alternate index record has an associated PATH and the path should be allocated in the JCL that invokes this program. The DDNAME of the path should be DDNAME of the base cluster suffixed with 1 for the first alternate record clause, suffixed with n for nth ALTERNATE RECORD KEY clause in SELECT clause.
SELECT Statement-FILE STATUS IS WS-FILE-STAT1,WS-FILE-STAT2
WS-FILE-STAT1 should be defined as PIC X(02) in working storage section. After every file operation, the file status should be checked for allowable values. WS-FILE-STAT2 can be coded for VSAM files to get the VSAM return code (2 bytes), VSAM function-code (1 byte) and VSAM feedback code (3 bytes). This is a 6- byte field in working storage.
RESERVE Clause.
RESERVE clause [RESERVE integer AREA ] can be coded in the SELECT statement. The number of buffers to be allocated for the file is coded here. By default two buffers will be allocated if the clause is not coded. Since similar option is available in JCL, this is not coded in program.
RESERVE 1 AREA allocates one buffer, for the file in the SELECT statement.

Defining the file in FILE SECTION - FD
FD FILENAME
RECORDING MODE IS V/VB/F/FB
RECORD CONTAINS M CHARACTERS (TO N CHARACTERS)
BLOCK CONTAINS X CHARACTERS/RECORDS (TO Y CHARACTERS/RECORDS)
LABEL RECORDS ARE OMITTED/STANDARD
DATA RECORD IS FILE-RECORD.
01 FILE-RECORD PIC X(nnn).
FD-RECORD CONTAINS
It specifies the length of the record in terms of bytes. (It will be RECORD contains m to n CHARACTERS for variable format files)
FD-BLOCK CONTAINS
It specifies the physical record size. It can be mentioned as number of logical records OR number of characters, that is multiple of logical record length. It is suggested to code BLOCK CONTAINS 0 RECORDS so that system will decide the optimum size for the file based on the device used for storing the file. BLOCK CONTAINS clause is treated as comments for VSAM files.
Advantage of Blocking:
1.I-O time is reduced as n numbers of records are read into main memory buffer during an I-O.
2.Inter record gap is removed and the gap exist only between blocks. So memory wastage due to IRG is avoided.
FD-RECORDING MODE IS
It can be F (FIXED) V(VARIABLE) FB(FIXED BLOCK) VB(VARIABLE BLOCKED)
Variable record file identification:
If there is no recording mode/record contains clause, it is still possible to identify variable length records. If there is an OCCURS depending on clause or there are multiple 01 levels and every 01 level is of different size, then the file would be of variable length. Multiple 01 level in File section is an example for implicit redefinition.
FD-LABEL RECORDS Clause
As a general rule, LABEL RECORDS are STANDARD is coded for Disk and Tape files, LABEL RECORDS ARE OMITTED is coded for printer files. In COBOL74, this clause is a mandatory clause whereas COBOL85 made this as optional.
FD-DATA RECORD IS Clause
It is used to name the data record(s) of the file. More than one record can be coded here.
OPEN STATEMENT
Syntax:
OPEN OPENMODE FILENAME
OPENMODE can be INPUT OUTPUT I-O EXTEND

INPUT :- File can be used ONLY-FOR-READ purpose.
OUTPUT :- File can be used ONLY-FOR-WRITE purpose.
I-O :- File can be used FOR READ, WRITE and REWRITE purpose.
EXTEND :- File can be used FOR appending records using WRITE.
CLOSE statement.
The used files are closed using CLOSE statement. If you don't close the files, the completion of the program closes all the files used in the program.
Syntax:
CLOSE FILENAME
OPEN and CLOSE for TAPE files - Advanced
If more than one file is stored in a reel of tape, it is called as multi-file volume. When one file is stored in more than one reel of tape, it is called as multi-volume label. One reel is known as one volume. When the end of one volume is reached, automatically the next volume opens. So there is no special control is needed for multi volume files.
OPEN INPUT file-1 [WITH NO REWIND | REVERSED]
OPEN OUTPUT file-2 [WITH NO REWIND]
CLOSE file-3 [{REEL|UNIT} [WITH NO REWIND| FOR REMOVAL]
CLOSE file-3 [WITH NO REWIND|LOCK]
UNIT and REEL are synonyms.
After opening a TAPE file, the file is positioned at its beginning. When opening the file if the clause REVERSED is coded, then the file can be read in the REVERESE direction. (Provided hardware supports this feature)
When you close the file, the tape is normally rewound. The NO REWIND clause specifies that the TAPE should be left in its current position.
CLOSE statement with REEL option closes the current reel alone. So the next READ will get the first record of next REEL. This will be useful when you want skip all the records in the first reel after n number of records processing.
Since TAPE is sequential device, if you create multiple files in the same TAPE, then before opening the second file, first file should be closed. At any point of time, you can have only one file is active in the program. In addition to this, you have to code MULTIPLE FILE clause in the I-O control paragraph of environment division.
MULTIPLE FILE TAPE CONTAINS OUT-FILE1 POSITION 1
OUT-FILE3 POSITION 3.
The files OUT-FILE1 and OUT-FILE3 used in the program are part of a same TAPE and they exist in first and third position in the tape. Alternatively, this information can be passed from JCL using LABEL parameter.
READ statement
READ statement is used to read the record from the file.
Syntax:
READ FILENAME [INTO ws-record] [KEY IS FILE-KEY1]
[AT END/INVALID KEY imperative statement1]
[NOT AT END/NOT INVALID KEY imperative statement2]
END-READ
If INTO clause is coded, then the file is directly read into working storage section record. It is preferred as it avoids another move of file-section-record to working-storage-record followed by simple READ. READ-INTO is not preferred for variable size records where the length of the record being read is not known.
KEY IS clause is used while accessing a record randomly using primary/alternate record key.
AT END and NOT AT END are used during sequential READ of the file.
INVALID KEY and NOT INVALID KEY are used during random read of the file. Before accessing the file randomly, the key field should have a value before READ.
WRITE Statement
Write statement is used to write a new record in the file. If the file is opened in EXTEND mode, the record will be appended. If the file is opened in OUTPUT mode, the record will be added at the current position.


Syntax:
WRITE FILE-RECORD [FROM ws-record]
[INVALID KEY imperative statement1]
END-WRITE
FROM clause avoids the explicit move of working storage record to file section record before WRITE.
REWRITE Statement
REWRITE is used to update an already read record. To update a record in a file, the file should be opened in I-O mode.
Syntax:
REWRITE FILE-RECORD [FROM ws-record]
[INVALID KEY imperative statement1]
END-REWRITE
START Statement
START is used with dynamic access mode of indexed files. It establishes the current location in the cluster for READ NEXT statement. START itself does not retrieve any record.
Syntax:
START FILENAME KEY is EQUAL TO/NOT LESS THAN/GREATER THAN key-name
[INVALID KEY imperative statement1]
END-START.
DELETE Statement
DELETE is used to delete the most recently read record in the file. To delete a record, the file should be opened in I-O mode.
Syntax:
DELETE FILENAME RECORD
[INVALID KEY imperative statement1]
END-DELETE.
File Error - Handling
There are chances for failure of any file I-O processing. The failure of an I-O operation can be accepted or cannot be tolerated. The severity of failure has to be defined in the program design stage.
Let us assume that we don't have any error handling in our program. In this case, for example, if you don't have a specific record in the file, the random read of that record would immediately terminate the program with error 'record not found'.
Error Handling Clauses Provided by COBOL.
The sudden termination can be avoided by handling this error, with INVALID KEY clause of READ. Based on the importance of the record and business rule, we can continue our program with next record or terminate the program properly.
AT END is another error handling clause provided by COBOL. But there is no way to handle all such errors in this way.
Assign file-status and take the responsibility.
The second method is, assigning file-status to the file in the SELECT clause and checks the file status after each and every I-O and ensures that the value of status code is one of the allowable values. If it is not an allowable return code, then abnormally end the program with error statements that would be easier to debug.
But we have to do this checking after each and every I-O operation.
This is MOST PREFERRED ERROR HANDLING METHOD in structured programming.
Declaratives - USE statement
COBOL provides an option to group all the possible errors of specific operation(s) in a place and that will be automatically invoked during the respective operation(s) of any file. This avoids redundant code.
This is done in DECLARATIVE section of the procedure division. DECLARATIVE should be the first section in the procedure division if coded.
PROCEDURE DIVISION.
DECLARATIVES.
USE-PROCEDURE SECTION.
USE AFTER EXCEPTION PROCEDURE ON INPUT.
ERROR-PROCEDURE.
Check the file-status code for validity.
END-DECLARATIVES.
Whenever there is an error in the processing of ANY FILE opened in INPUT mode, then the control comes to ERROR-PROCEDURE. The validity of error should be checked in this paragraph and allow or restrict the process down, based on severity of error code.
Syntax:
USE AFTER STANDARD ERROR|EXCEPTION PROCEDURE ON INPUT|OUTPUT|I-O|EXTEND| file-1
If INPUT is coded, the following procedure will be executed for every operation involved in any file that is opened in INPUT mode. OUTPUT, I-O and EXTEND have the same meaning but the mode is different.
If file name (file-1) is coded in the USE statement, then all the input-output operation of that specific file will be checked.
ERROR and EXCEPTION are synonyms.
The Procedure written in a DECLARATIVE section should not refer to any non-declarative procedure written after the end procedure and vice-versa.
I-O-CONTROL - SAME AREA AND SAME RECORD AREA
RESERVE clause of SELECT statement specifies the number of buffers to be allocated for a file. SAME AREA allows more than one file to use the same buffer area. This will be very useful when the program must work with a limited memory space. But the problem is only one file should be open at a time if SAME AREA is coded.
Syntax:
SAME AREA FOR file-1 file-2 file-3.
If SAME RECORD AREA is coded, then the buffer is not shared but only the record area is shared. So more than one file can be in open state. We should be careful while filling in the record area of the output file. This may destroy the record read most recently.
Syntax:
SAME RECORD AREA FOR file-1 file-2 file-3.
SAME SORT AREA allows more than one sort/merge work files to use the same area. The sort work files are automatically allocated when file is opened and de-allocated when file is closed. As the sort file is automatically opened and closed during a SORT and two sort files cannot be opened at a time, this clause may not be useful.
Syntax:
SAME SORT|SORT-MERGE AREA for file-1 file-2. File-1 or file-2 should be a SD file.
I-O CONTROL- RERUN Clause
RERUN ON rescue FOR EVERY integer RECORDS on file-1
This will cause checkpoint to be taken for every interger-1 records processing of file-1. If the program ABENDED before the complete processing of the file-1, then the program will restart from integer+1ST record instead of first record. The rescue file details should be mentioned outside the program and it varies from installation to installation.
ENTRY statement
ENTRY statement establishes an alternate ENTRY point in a COBOL called sub-program. When a CALL statement naming the alternate entry point is executed in a calling program, control is transferred to the next executable statement following the entry statement. Except when a CALL statement refers to an entry name, the ENTRY statements are ignored at run-time.
Matching Logic
If you have been given two files of similar type, say master and transaction file and you are requested to update the master file with transaction file information for existing records and prepare a report of new transactions and deleted transactions, then you should go for what is called Matching logic. This is also known as co-sequential processing.
Sort both the files on key and compare the keys. If the keys are matching then update the file. If you find any record that is found in transaction but not in master file, then that is new addition and the reverse is deletion. If the master key is greater than transaction key, then that corresponds to the first case and reverse is the second case.
This can be easily done in JCL using ICETOOL.

No comments: